Mains input via 5×35mm² H07 rubber cable w/ CEE plug 3×125 A input via male CEE connector (fixed to the back panel or with 1m length 5×35mm² H07 rubber cable) 3×1P C125A circuit breakers for mains protection Two 3-phase 63 A outputs on CEE63A 5P socket protected with 3×1P C63A 6 kA MCBs and 63A/300 mA RCDs (Power-125B only) Four 3-phase 32A outputs on CEE32A 5P socket protected with 3×1P C32A MCBs and 40A/30 mA RCDs AUX 16 A Schuko outputs on the back with RCBO (MCB-RCD combination; C16A/30 mA) Více informací
Mains input via 5×35mm² H07 rubber cable w/ CEE plug
3×125 A input via male CEE connector (fixed to the back panel or with 1m length 5×35mm² H07 rubber cable)
3×1P C125A circuit breakers for mains protection
Two 3-phase 63 A outputs on CEE63A 5P socket protected with 3×1P C63A 6 kA MCBs and 63A/300 mA RCDs (Power-125B only)
Four 3-phase 32A outputs on CEE32A 5P socket protected with 3×1P C32A MCBs and 40A/30 mA RCDs
AUX 16 A Schuko outputs on the back with RCBO (MCB-RCD combination; C16A/30 mA)
Digital multimeter (DMM) to monitor the main features of the incoming power line:voltage between phases
voltage between phases and neutral
current on each phase
line frequency
operating time
peak and average display
Additional analogue current meter (only in Power-125B)
Dimensions | Power-125A: 19” rack 6U 484×264×250 mm (W×H×D, plus connectors) Power-125B: 19” rack 9U 484×396×250 mm (W×H×D, plus connectors) |
---|---|
Weight | Power-125A: 25 kg (net), 28 kg (gross) Power-125B: 30 kg (net), 33 kg (gross) |